ISO IEEE 11073 PDF

ISO addresses the definition and structuring of information that is communicated or referred to in communication between application entities. ISO/IEEE describes an IrDA-based, cable-connected local area network (LAN) for the interconnection of computers and medical devices and. The application of the Ethernet family (IEEE Std ) of protocols for use in medical device communication is addressed in ISO/IEEE

Author: Shaktiktilar Nebar
Country: Bhutan
Language: English (Spanish)
Genre: Technology
Published (Last): 4 June 2013
Pages: 115
PDF File Size: 5.49 Mb
ePub File Size: 1.12 Mb
ISBN: 662-9-68990-288-1
Downloads: 47701
Price: Free* [*Free Regsitration Required]
Uploader: Nikozuru

Transport profile — Infrared wireless. The Manager requests the Agent through this service to create a scanner object itself, and to fix the scanner object on one or more values.

From Wikipedia, the free encyclopedia. It provides the data. Within this, objects and their arrangement in a Domain Information Model for vital signs data transmission are defined.

This small package is related within the medical package. Storing Patient related data in online or offline archives is the idea for objects in the archival package.

Programmatically these codes are defined as constants, those can be used by a pseudonym. There are objects used for influenceing the jso of measuring for example the SetRangeOperation object and objects for direct remote control of medical devices for example the ActivateOperation object.

P P P P P A complete session roundtrip starts up with the disconnected state, is transferred by multiple stages to the initialized state, in what the actual data transfer shall be done, and ends with the disconnected state. Analytical instruments — Point-of-care test. Scanning data in other objects and generation of event reports, who ixo be sendend, is the sense of this objects.

Transport profile — Cabled Ethernet. This report is sent back to the Manager. The communication model describes the layers 5 to 7 of the OSI 7-layer model. It has services available, that controlling the association assembly and disassembly.

  6AV6 545 0DA10 0AX0 PDF

The information model defines the modeling, formatting and the syntax for transmission coding of the objects. Articles needing additional references from February All 11073 needing additional references. These packages are developed very open, so that different communication profiles and interfaces to proprietary device interfaces can be built.

During the association phase, the 11073 state will be reached. As an example, the FastPeriCfgScanner object Fast Periodic Configurable Scanner is specially constructed for the requirements of real-time data exchange in conjunction with the RealTimeSampleArray object to transmit live data from egc devices. A possible association and their condition is negotiated here, no MMOs are transmitted over this module. For Example, the Patient Archive object can idee vital signs data, demographic data and treatment data in one object.

This page was last edited on 22 Septemberat In most use cases the manager is only used to remotely monitor and display agent data, but in some cases it may ieo remotely control the agents. Guide — Guidelines for the use of RF wireless technology. The last one can be used for time synchronization of medical device data.

From a historic view, the standard was developed for the first time in the early 90s, jso package has to be reconstructed. Objects for additional services around vital signs data objects, are defined also here. For published and draft standards search for ” at: The Battery object and the Clock object are further objects in this package.

ISO/IEEE 11073

Views Read Edit View history. Application profile — Ifee standard. Health informatics — PoC medical device communication — Part This package is built on so-called scanner objects in different derivations. The complete communication sequence can be very complex. The scanner objects have a wide range of different attributes e.

  CAZU ZEGERS PDF

Besides the plain agent-manager application, hybrid systems over multiple stages are possible.

ISO/IEEE – Wikipedia

Objects, groups of objects attributes or single attributes are encoded by ASN. Within this standard nomenclature codes are defined, these give the possibility to clearly identify objects and attributes in relation to the so-called OID-Code [1]. The data updates from Agent to Manager now occur automatically through the scanner object.

It’s subdivided in a communication model and an information model.

This layer contains the encoding of object data. The standards draw upon earlier IEEE standards work, but differ from this earlier work due to an emphasis on devices for personal use rather than hospital use and a simpler communications model.

Nomenclature — Annotated ECG. They comprise a family of standards that can be layered together to provide connectivity optimized for the specific devices being interfaced. By using this site, you agree to the Terms of Use and Privacy Policy. The standards are targeted at personal health and fitness devices such as glucose monitors, pulse oximeters, weighing scales, medication dispensers and activity monitors and at continuing and acute care devices such as pulse oximeters, ventilators and infusion pumps.