First edition. Non-destructive testing of steel tubes —. Part 1: Automated electromagnetic testing of seamless and welded (except. DIN EN ISO Non-destructive testing of steel tubes – Part 1: Automated electromagnetic testing of seamless and welded (except. Find the most up-to-date version of ISO at Engineering

Author: Gardabar Goltitaur
Country: Djibouti
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 5 January 2010
Pages: 397
PDF File Size: 12.92 Mb
ePub File Size: 18.11 Mb
ISBN: 975-1-39785-808-4
Downloads: 98972
Price: Free* [*Free Regsitration Required]
Uploader: Goltilrajas

By agreement between the purchaser and manufacturer, the suspect area may be retested by other non-destructive techniques and test methods to agreed acceptance levels. They are widely used, often during production, for quality assurance.

We use cookies to make our website easier to use and to better understand your needs. Each segment coil shall be checked with the reference tube, and the three holes shall be displaced as follows: The excitation frequency applied to the test coil determines the extent to which the induced eddy current intensity penetrates the tube wall. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting.

Automated electromagnetic testing of seamless and welded except submerged arc-welded steel tubes for the verification of hydraulic leaktightness. For details of these and other benefits contact Membership Ad- ministration.

Non-destructive tests are primarily used on pressure-retaining pipes for chemical, petrochemical and power station industries. It is recognized that longitudinal imperfections are not 18093-1 detectable unless they have a significant transverse component oblique.

BS EN ISO 钢管的无损检测–第1部分:用于验证水压密实性的无缝和焊接钢管(埋弧焊除外)自动电磁检测 – MBA智库文档

NOTE The pancake coils in a and b can have different forms, e. For this reason, the technique 110893-1 predominantly transverse imperfections having a minimum length dependant on the circumferential dimension of the transducer. After checking 18093-1 the remaining thickness is within tolerance, the tube shall be tested as previously specified.

  DOES-UC30 FORM PDF

Automated electromagnetic testing of seamless and welded except submerged arc-welded steel tubes for the verification of hydraulic leaktightness Status: The work of preparing International Standards is normally carried out through ISO technical committees.

It supersedes BS EN Ne to Checkout Continue Shopping. For this reason, this technique detects longitudinal imperfections with a minimum length dependent on the width of the test coil and the inspection helical pitch. You may experience issues viewing this site in Internet Explorer 9, 10 or Accept and continue Learn more about the cookies we use and how to change your settings.

If the document is revised or amended, you will be notified by email. ISO consists of the following parts, under the general title Non-destructive testing of steel tubes: BSI also holds the copyright, in the UK, of the publications of the international standardization bodies. ISO ; b statement of conformity; c any deviation, by agreement or otherwise, from the procedures specified; d product designation by steel grade and size; e type and details of inspection technique s ; f equipment calibration method used; g description of the reference standard acceptance level; h date of test; i operator identification.

It is incorporated by Royal Charter. This part of ISO can also be applicable to the testing of hollow sections.

Wn shall not be held responsible for identifying any or all such patent rights. This does not preclude the free use, in the course of implementing the standard of necessary details such as symbols, and size, type or grade designations. The same equipment settings, for example frequency, sensitivity, 1893-1 discrimination, filtering and magnetic saturation, shall be employed.

In this case, the manufacturer shall demonstrate that the test sensitivity achieved using the reference hole and the equipment settings, for example signal rate filtering, is essentially equivalent to that obtained when using the reference notch.

  CALDERA ROCA P30 PDF

BS EN ISO 10893-1:2011

As the voice of the U. Need more than one copy? Automated electromagnetic testing of seamless and welded except submerged arc-welded steel tubes for the verification of hydraulic leaktightness ISO Add to Alert PDF. It is applicable to the inspection of tubes with an outside 18093-1 greater than or equal to eb mm, when testing with eddy current, and greater than 10 mm when testing with flux leakage method.

This first edition cancels and replaces ISO A list of organizations represented on this committee can be obtained on request to its secretary.

Users are responsible for its correct application. Search all products by. Users of British Stan- dards should 108931 sure that they possess the latest amendments or editions.

This part of ISO specifies requirements for automated electromagnetic testing of seamless and welded steel tubes, with the exception of submerged arc-welded SAW tubes, for verification of hydraulic leak-tightness in substitution of hydrostatic test. Please first verify your email before subscribing to alerts.

For dated references, only 108993-1 edition cited applies. If the document is revised or amended, you will be notified by email. During the fIux leakage testing of tubes, the sensitivity of the test is at a maximum at the tube surface adjacent to the magnetic transducer and decreases with increasing tube thickness due to effective diminishing flux diversion from imperfections at the tube bore surface in relation to that at the external surface. Please first log in with a verified email before subscribing to alerts.