ASTM D4329-05 PDF

The Test Protocol that was followed is an adaptation of ASTM D where 1E 1E Buy ASTM D PRACTICE FOR FLUORESCENT UV EXPOSURE OF PLASTICS from SAI Global. ASTM D Standard Practice for Fluorescent UV Exposure of Plastics. This practice covers specific procedures and test conditions that are applicable.

Author: Nebei Goltilar
Country: Azerbaijan
Language: English (Spanish)
Genre: Video
Published (Last): 16 November 2013
Pages: 61
PDF File Size: 14.42 Mb
ePub File Size: 7.5 Mb
ISBN: 211-3-70677-521-4
Downloads: 62491
Price: Free* [*Free Regsitration Required]
Uploader: Dozragore

Expose replicates of the test specimen and the adtm specimen so that statistically signicant performance differences can be determined NOTE 8—Fischer illustrates use of rank comparison between test and control materials in specications.

A superscript epsilon e indicates an editorial change since the last revision or reapproval. The standardized time period needs to consider conditioning prior to testing. This method is preferred over evaluating materials after an arbitrary exposure time or radiant exposure. Proceed to Checkout Continue Shopping.

This practice also covers the preparation of atsm specimens, the test conditions best suited for plastics, and the evaluation of test results.

Accelerated Weathering (QUV) ASTM G, ASTM D, ASTM D, ISO

Enabling you to identify and mitigate the intrinsic risk in your operations, supply chains and business processes. D4329-0 factors include regulation of line voltage, temperature of the room in which the device operates, temperature control, and condition and age of the lamp.

Auditing Consulting Sourcing Training. You may delete a document from your Alert Profile at any time. Periods of Exposure and Evaluation of Test Results 8.

  FOTOLECTURA PAUL SCHEELE PDF

ASTM D – 05 Standard Practice for Fluorescent UV Exposure of Plastics

Your comments will receive careful consideration at a meeting ast the responsible technical committee, which you may attend. NOTE 2—Additional information on sources of variability and on strategies for addressing variability in the design, execution, and data analysis of laboratory-accelerated exposure tests is found in Guide G Whether your business is local or global, we can ensure your products meet quality, health, environmental, safety, and social accountability standards for virtually any market around the world.

You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. Attach porous specimens to a solid backing such as aluminum that can act as a vapor barrier.

If four specimens are stacked vertically, then the specimens should be repositioned vertically three times during the test. Already Subscribed to this document.

Accelerated Weathering (QUV) ASTM G154, ASTM D4329, ASTM D4587, ISO 4892

Control of ambient temperature is particularly critical when one apparatus is stacked above another, because the heat generated from the lower unit can interfere with the operation of the units above.

As the voice of the U. D — 05 Standard Practice for Fluorescent UV Exposure of Plastics1 This standard is issued under the xed designation D ; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. Last previous edition approved in as D – NOTE 6—An example of a statistical analysis using multiple-laboratory and exterior exposures to calculate an acceleration factor is described by Simms.

  HERACLITUS WHEELWRIGHT PDF

Calculate retention of characteristic property in accordance with Practice D when it is reported. NOTE 4—This is especially important when mechanical properties are being investigated. Assurance Testing Inspection Certification.

Your Alert Profile lists the documents that will be monitored. Standards can be obtained from appropriate standard authorities. Typically, flat plaques or disks are used for accelerated weathering studies. All specimens shall be exposed simultaneously in the same device. Signicance and Use 4. Please first log in with a verified email before subscribing to alerts.

For instance, if two specimens are stacked vertically in each holder, then the top and bottom specimens should switch places halfway through the test. No direct correlation can be made between accelerated weathering duration and actual outdoor exposure duration.

Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility.

Through our network of over 43, people in 1, laboratories and offices in countries, Intertek provides quality and safety solutions to a wide range of industries around the world. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Subscription pricing is determined by: Instrumental measurements are recommended whenever possible.